ʻO MV Switchgear Component

  • vacuum interrupter

    mea hoʻokiwikā holo

    Hoʻohana ka mea hoʻowahāwahā i ka ceramic nalu e like me ka shell insulate, ʻo ka mea pili iā CuCr alloy, ka lōʻihi o ke kīʻaha kīʻaha magnetic longitudinal, me ka hiki i ka haʻihaʻi kiʻekiʻe, pae hoʻokiwikā kiʻekiʻe, hiki i ke pio pio ikaika, ola lōʻihi, ka liʻiliʻi a me ka mālama maʻalahi, ʻaʻohe pahū. makaʻu, ʻaʻohe haumia, kani haʻahaʻa a pēlā aku. Loipālākiō ʻōnaehana waiwai Loipālākiō anakahi uila 12kV Loipālākiō i kēia manawa 630A Loipālākiō alapine helu 50Hz Loipālākiō manawa pōkole mana pinepine i ka anakahi uila (1 min) 42k ...
  • Indoor SF6 for switchgear 10KV 630A Gas Insulated Load Break Switch LBS Indoor Isolating switch

    I loko o SF6 no ka switchgear 10KV 630A Ke Kinoea Insulated Load Break Switch LBS i loko o ka hale hoʻokaʻawale

    Ka hoʻohana ʻana i nā kūlana kaiapuni: 1. Kiʻekiʻena: ≤2000m; ʻO ka ʻōlaʻi ʻōlaʻi: ʻaʻole i ʻoi aku ma mua o ʻewalu 2. Mahana wela o ke ea: ʻaʻole kiʻekiʻe ma mua o + 40 ℃, ʻaʻole ma lalo o -30-. ʻO ka awelika o ka mahana e pili ana i kēlā me kēia lā ʻaʻole i ʻoi aku ma mua o 90%, ka awelika o ka mahina ma mua o 90%. 3. ʻAʻole kūpono ke kahua hoʻonohonoho me ka haʻalulu pinepine a me ka ikaika no ka pūnaewele hoʻonohonoho me ka mahu wai, ka ʻaukā, ka waiho ʻana o ka lāʻau make, ka paʻakai paʻakai, ka lepo a me ka lepo, nā pōʻino ahi a me nā pahū e maopopo leʻa i ka perfo ...
  • Incoming operating mechanism for gas insulated switchgear

    ʻO ka hana hana e hiki mai ana no ka switchgear insulated gas

    SF6 Insulated Switchgear Last: Manual / Motor: A, paʻakikī interlock / B, palupalu interlock Kōmike Parameter: ʻikepili Unit Parameter Switch contact pressure standard N 190-210 Open tri-phase dissimilar ms ≤2 Close tri-phase dissimilar ms ≤2 Opening average wikiwiki m / s 3-6 Pane ʻana i ka awelika m / s 4-6 Wīwī pae pae maʻamau m / s ≤2 ʻEkolu manawa pae puka ° 88 ° Ke ola mīkini Nā manawa 10000 Ka ikaika o ka hana N11010 Kaha:
  • outgoing mechanism

    ʻōnaehana hele aku

    SF6 Insulated Switchgear Last: Manual / Motor: A, paʻakikī interlock / B, palupalu interlock Kōmike Parameter: ʻikepili Unit Parameter Switch contact pressure standard N 80-190 Open tri-phase dissimilar ms ≤2 Close tri-phase dissimilar ms ≤2 Opening average wikiwiki m / s 3-6 Pane ʻana i ka awelika m / s 4-6 Wīwī pae pae maʻamau m / s ≤2 ʻEkolu manawa pae puka ° 88 ° Ke ola mīkini Nā manawa 10000 Ka ikaika o ka hana N11010 Kaha:
  • 12kV 630A loadbreak switch

    12kV 630A hoʻouka hoʻouka

    ʻIkepili Parameter 12KV ʻImi Unit Parameter Loipālākiō anakahi uila KV 12 Loipālākiō alapine HZ 50 Loipālākiō kālā A 630 Loipālākiō pōkole huakaʻi e ku cu Manawa 10000 Wehe i ka huakaʻi helehelena like ʻole ≤2 Kahi huakaʻi panina dissimilar ms ≤2 Wehe i ka awelika o ka wikiwiki m 3 s ʻO ke aniani wikiwiki m / s 4-6 Wāwahi kaomi hana ʻāpana: 22KV -28 ...
  • SF6 Insulated Load Break Switch

    SF6 Insulated Load Break Switch

    Overview ʻO ke kuapo ukana kahi ʻano switchgear me kahi mea pio pio maʻalahi. Hoʻohana ia i ka gas SF6 e like me ka mea hoʻopili a me ka medium extinguishing medium. Hiki ke hoʻohana ʻia e like me ka panina a me ka haki ʻana o ka ukana i kēia manawa a me ka nui o ke au. Hiki ke hoʻohana ʻia e like me ka panina a haki ʻole i ka ukana. ʻO nā laina, nā transformer no-load a me nā panakū capacitor, a pēlā aku. Ma ka hoʻohui i ka lōʻihi ola, ikaika wāwahi fo ...